| Revised Summary of Requirements for Industry Review of equipment evaluated to the Standard for Switchboards, UL 891 | 2006-09-20 |
| This bulletin announces a revision to the Summary of Requirements for the ongoing file review for the eleventh edition of the UL Standard for Switchboards, UL 891. The date of the revision was July 26, 2005, and the effective date for these requirements is July 26, 2007. The change to the Standard that is the focus of this revision was originally identified as a correction to a typographical error, and for that reason was not acknowledged in the Summary of Requirements. It has been determined that this change may represent a substantive change to some manufacturers, especially with the consideration that the Standard itself serves as part of the Follow-Up Service Inspection Procedure. The Summary of Requirements are provided on the UL website in their entirety. Attached, as Appendix A, is an errata for the Summary of Requirements that details the revision that is the subject of this bulletin. Questions regarding the requirements identified in the Summary of Requirements or the status of the file review process should be directed to the responsible UL Staff. Please see Appendix B of this bulletin regarding designated responsibility for the subject product category. | |
| New requirements on Portable Luminaires UL 153 | 2006-02-20 |
| 1. Restricted Maximum Ampere Rating For a unit with an 15 ampere attachment plug and 125 volt configuration, the maximum ampere rating of the portable luminaire shall be restricted to 12A. 2. Lampshade to be regarded as a removable part For Tungsten halogen units, if the lampshade can be removed without the use of tool, it shall be treated as a removable part during adjacent surface and overlamping abnormal operation Tests and lamp guard, lamp containment barrier and UV filter security test. The above revisions shall become effective on June 28, 2007, so it is a good idea for you pay attention to the above changes | |
| UL 153, Portable Luminaries | 2005-09-01 |
| Engineering Cut-off Date: 12/18/2005 Effective Date: 02/18/2006 27.1.5, Section 131A New requirements for series/parallel light strings having leads smaller than 18 AWG, including performance tests. 33.4, 33.4.1 Interconnecting receptacles are now required to have a different supply and load end configurations. 68.3.3, 69.3.4.1 Wall and under-shelf units require grounding if they are permanently mounted and need tools to secure. 72.2.1 New requirements for hanging type units provided with plastic hooks, including performance test. 127.3, 188.2.3 New requirements for pot style portable lights intended for closed top cabinets only; allows up to 150C on enclosure. 188.1.3.1, 188.1.4.1, 188.1.5.1, 188.1.6.1Revised installation instructions for portable cabinet lights. | |
| Home | Our Services | Testing Categories | Our Qualification | Product Sourcing | Jobs Openings | Recent News | Contact Us |
Questions Or Enquiries: (852) 2707 4383
|
![]() |
|